Smileline
Patients

Implant planning

Open a patient's CBCT and intraoral scans in Implant planning straight from their record, and save the plan to it.

Implant planning is where you plan implants on a patient's CBCT: the arch, nerve canals, implants, surgical guides and reports, in 3D and in axial, panoramic and cross-section views. From the patient's record it opens in a new browser tab with their CBCT, and their intraoral scan if you want it, already loaded. The plan saves to the patient's record as you work, and opening the CBCT again brings it back.

Implant planning is in ⋯ › Open in on the record's Files tab for every practice, for anyone who can see the patient's documents. Its line shows the date of the patient's latest CBCT, or Needs a CBCT. Implant planning always needs a CBCT; scans are optional.

Open a patient in Implant planning

Open the patient's record and go to Files.

Click ⋯, then Implant planning under Open in. Implant planning opens in a new tab with the patient's name and date of birth, how many CBCT files they have, and their scans.

Pick the scan to open with the CBCT, or No scans, and click Open. Implant planning downloads the files and opens the case.

A CBCT's tile on Files opens Implant planning on that scan directly, with no choice of series to make, and with every file of the scan, whatever Type each file is filed as. If the scan was archived or moved to another patient meanwhile, Implant planning says so and opens nothing else in its place.

When the patient has no CBCT on file, Implant planning opens your computer's file picker instead, as Add files does, with a line saying what to add: pick the patient's CBCT DICOM files. Once they are on Files, click Implant planning in ⋯ again. If your role can't add images, Smileline says the patient has no CBCT on file.

What Implant planning opens

  • The CBCT: every DICOM image of type CBCT on the patient's Files tab, except archived ones. The type is read from the file when it is uploaded; if it was missed, set the image's Type to CBCT under its Details. A CBCT can be a file per slice or one file holding every slice, as some scanners save it. A DICOM file among them that holds no image, such as a report the scanner saved beside the slices, is passed over. When the files hold more than one series (two scans taken on different days, say), Implant planning asks which one to plan on, showing each series' date, number of slices and description. A file whose series Implant planning can't read is listed on its own and never opens with another file.
  • One scan (in the UK, the US and Ireland, with a connected scanner): pick one of the patient's filed scans, newest first. Its upper jaw, lower jaw and bite open as the jaws they were filed as, and Implant planning matches them to the CBCT. Supporting files and 7z archives don't open in Implant planning.

Images waiting under New from imaging open only once they are filed on the patient.

The patient's other 3D files

Once the case is open, Implant planning asks Import 3D files from the patient's record? when the patient's Files tab holds STL, PLY, OBJ or zip files the case doesn't have yet (archived files and 7z archives are left out). Each file shows its picture, once Smileline has made it, and the object type Implant planning would give it (the treated jaw's scan is the Anatomy, the other jaw's the Antagonist).

  • Untick the files you don't want, then click Import. The files of one scan are imported together, so Implant planning matches them to the CBCT as one scan. If the case already has objects of those types, Implant planning asks first, as Import 3D objects does, and a case keeps one Anatomy.
  • Not now imports nothing. Implant planning asks again the next time you open the CBCT, and the files stay under Import on Data Import.

If a file doesn't download, Implant planning says so and offers Retry or Cancel.

Import 3D objects

On Data Import, Import opens Import 3D objects, where you bring several files into the plan at once. Its files come in groups, each with a box to tick or untick the whole group:

  • Patient's files, opened from Smileline: the 3D files on the patient's record. A file already in the plan shows Already in this plan and can't be ticked again.
  • Kept with this case: files the case keeps that no object uses now (an object you deleted, say). It shows only when there are some.
  • From this computer: drop STL, PLY, OBJ or zip files on the strip, or use Choose files or Choose folder. A scan's texture (MTL, PNG, JPG) comes along with the scan that names it and shows as texture on it. A file that isn't a 3D file is listed under Not added, with why.

Every file is ticked, except one already in the plan. For each one pick its Object name (the treated jaw's scan starts as the Anatomy, the other jaw's as the Antagonist) and its Position: Match to the CBCT, Keep original position, or Same as an object already in the case. Click a file to see it on the right, with its size, date and triangles. Files from one scan show the scan's date as an export and are matched to the CBCT together; so are the files you add in one pick or drop, and the meshes of one zip. A zip on the patient's record brings every mesh it holds, each as an object of the type its file's name suggests.

The line at the foot counts what Import will do. Click Import and the number of objects:

  • the patient's files are downloaded first (Retry or Cancel if one doesn't);
  • one file set to Match to the CBCT opens the matching wizard, as before; several are matched to the CBCT by themselves, each scan's files together (while a matching wizard is open, nothing is imported: finish or close it, then click Retry);
  • files set to Keep original position or Same as are placed at once.

If the case already has an object of a type you chose, Implant planning asks once, naming them: Yes replaces them, No adds the new ones beside them. It asks once it knows what each file brings (a zip's meshes are read first), and a zip with no 3D object in it imports nothing and changes nothing. A case has one Anatomy. Undo takes the whole import back in one step (the matching wizard keeps its own steps).

Downloading the files

Implant planning downloads the files with your own Smileline sign-in, six at a time, with a progress bar and Cancel. Each file is a recorded read of that document, as when you open it on the record. If some files fail to download, Implant planning says how many and why, and Retry downloads only those files.

A browser tab can hold about 4.3 GB of files for Implant planning. Before it downloads anything, Implant planning checks that the files fit:

  • If the patient's CBCT files come to more, archive the CBCT files you don't plan on, on their Files tab. Archived files stay on the record, and Implant planning leaves them out.
  • Implant planning reads a copy of each file it opens, so the series you picked and the scan must come to half of that, about 2.1 GB. If they come to more, open the CBCT with No scans, or with another scan. Once you pick a series, Implant planning lets go of the other series it downloaded. When you click Open again after Exit, it lets go of the files of the case you had open (your plan and what Implant planning made for it stay).

Implant planning always opens a CBCT at full detail when your computer can. When a CBCT is too large for that (a very fine scan of a large area), Implant planning asks Open it at half resolution?:

  • Open at half resolution averages each 2 × 2 × 2 block of voxels into one: an eighth of the memory, with voxels twice the size. The top bar then shows Reduced resolution after the scan's size. The CBCT files themselves are unchanged, and the plan remembers the half resolution.
  • Cancel opens nothing and takes you back to the patient's files.

A CBCT too large even at half resolution doesn't open, and Implant planning says so.

A scan that was moved to another patient after Implant planning listed it doesn't download. Click Cancel, then open Implant planning again from the patient's record.

If you are not signed in, Implant planning offers Sign in and comes back to the patient afterwards. If your browser can't open the CBCT, close other tabs and try again, or use a computer with more memory.

Opening a CBCT again

Implant planning keeps a copy of each CBCT file it opens on your computer, encrypted, so the next time you open that CBCT it reads the files from there instead of downloading them, and shows Opening from this computer. Each time you click Open it still reads the patient's files from Smileline first: a file archived or moved to another patient since never opens, and its copy is deleted, and a file added since is downloaded and kept with the others.

  • Today's patients are copied ahead. Once Implant planning has been used in a browser, Smileline copies the CBCTs of the patients on today's diary (the site your Diary shows) to that computer while Smileline is open there, for anyone who can see the diary and the patients' documents. It copies two files at a time and looks again every hour, pauses while Implant planning is opening a scan, and stops when the computer is short of space.
  • The copies stay until the computer needs the space. The copies of the patients opened longest ago are deleted first, never those of a CBCT being opened.
  • Signing out locks them. When you sign out or switch practice, the copies stay on the computer, but nobody can read them until someone signed in to that practice opens the patient again.
  • An erased patient's copies are deleted the next time Smileline is opened on that computer (it checks once a day), and so are those of a patient no longer in your practice. A computer that never opens Smileline again keeps its encrypted copies.

A browser that can't keep files this way (an older Safari, a private window) keeps no copies, and Implant planning downloads the files every time.

Using a trackpad

On Implant planning's 3D views a trackpad works as you'd expect, and a mouse works exactly as before:

  • Pinch to zoom in or out where the pointer is.
  • Scroll with two fingers to zoom, as the mouse wheel does.
  • Click and drag to turn the model, as with the mouse.
  • Shift and two fingers move the model across the view.
  • In Safari, turn two fingers to roll the view.

The new view and the classic view

Implant planning has two views. Every tool is in both; only where they sit changes.

  • New view: the steps run as tabs across the top bar, and Layout, Reset, Screenshot, W/L, Ruler, Inspect, Undo and Redo sit on the left edge of the 3D view (in a narrow column beside the views when no 3D view shows). The 3D view's own buttons are two bars with names: the looks (X-Ray, Bones, Soft Tissues, Teeth) at the top, and what to show (DICOM, Implants, Abutments, Sleeves, Sectional View) with Scout (Planes, Lines, Hide) along the bottom. The step's panel is wider. The patient's name is at the top left with a dot for the save state: green once saved, grey while saving, amber when the plan isn't saved. Click the name to see the CBCT's details and the save state in words.
  • Classic view: the steps run down a rail at the left, and every tool is in the top bar.

To switch, click Settings in the top bar, choose New view or Classic view under General › View, and click OK. When you're signed in to Smileline, your choice is saved to your account and follows you to every computer you sign in on; otherwise it's kept on this computer. Until you choose, a note in the new view asks whether to Keep the new view or Use the classic view.

Changing the layout

Click Layout to choose which views a step shows. It is in the top bar, or in the new view among the tools at the left of the views.

  • Click a layout to put it on at once, behind the window, so you can see it before you close. For a single view, open the Fullscreen list and pick the view.
  • OK closes the window and keeps the layout. So do ✕ and Esc.
  • Cancel goes back to the step's own layout, whatever you picked.
  • Each 2D view has its name at its top left, beside a square in the view's colour. In the MPR layouts, the coronal view's square is blue and the sagittal view's green.

Implant planning saves the layout with the plan, so the case opens in it again. 3D + 3x1 + CPR XRay and 3D + Axial + 5x1 come back as you picked them: the cross-section in three or five slices and, for the first, the panoramic in RAY at 10 mm. A layout you pick while Adjust Orientation Axis is open is saved too. A plan or version saved without its layouts opens with each step's own layout and a 40 mm panoramic band, not the ones you had on. Undo brings yours back. VOI Settings, 3D Settings, Implant Planning and Reports / Export each keep their own layout. On the other steps the views are fixed and Layout is greyed.

Reading the 2D views

The letters on a view's edges name the side of the patient shown there: R right, L left, A front, P back, S head, I feet.

  • The axial and coronal views show the patient's right on the left of the screen, as if you faced the patient: R is on the left and L on the right. This is the same on every step and layout, with or without an implant selected.
  • The sagittal view has P on the left and A on the right.
  • In a view's W/L list, Auto Contrast spans the CBCT's whole grey range, the same whichever view or slice you pick it on.
  • To see several slices side by side, pick 3x1, 1x3, 3x3 or 5x1 in the view's layout list. Sp: then sets the distance between them. The largest distance in its list spreads the slices over the whole CBCT, and Custom (mm) takes any distance above zero that you type.
  • In the axial, coronal and sagittal views, the slices follow the slider's numbers from left to right and top to bottom: the lowest number comes first. The coloured lines of the other views cross each slice where those views cut it.
  • The Implant Report's panoramic and tangential sections carry the same letters. A picture that runs along one side of the jaw reads P and A at its sides, not R and L, and one that runs at an angle has no side letters.
  • A measurement made in a 2D view shows while it lies inside the slab that view draws (Th: in the view's header). At 1 mm it shows on its own slice and up to 0.5 mm either side. In the panoramic view it shows at every offset.
  • Cross Section Size in Settings sets how much of the jaw the cross-section and the tangential view show. That many millimetres fit the view's shorter side: at 50 mm a view 232 px high shows 4.6 px for each millimetre.
  • With Crosshair type set to Small, each line keeps only a short piece at its two ends, outside the rotate handles. Invisible hides the lines and keeps the handles.
  • With Use left mouse button instead of right for rotation in 3D off, a right drag turns the 3D view and a left drag does nothing. The wheel still zooms.
  • With Snap To Implant on in Settings, selecting an implant in an MPR layout turns the views to it. After you turn the implant with one of its rotate handles, the views turn to it again when you let go. Moving the implant only puts the views back on it.
  • The slider under the cross-section turns it about the vertical. The tangential view turns with it, so the two stay at right angles. Turning either view's line by its rotate handle in the axial view does the same.
  • Reset, beside Layout, fits every view again and puts the 3D view back as it opened. With an implant selected on the Implant Planning step, the views also go back onto that implant, the axial view square to it. With no implant selected, the planes go back as the case opens: the cross-section's turn and tilt and the tangential view's turn at 0, the axial view level.
  • On CPR Settings, the two thick views have their own thickness list (Th: in the view's header), from 0.3 mm to 150 mm.
  • Show Scout Planes on the 3D toolbar outlines the panoramic band round the jaw, in the CPR Color from Settings. Show CPR Scout Plane in Settings adds the band's own surface, tinted.

The curve and the nerves

On CPR Settings, the panoramic view is a band along the curve. Increase Panoramic Region and Decrease Panoramic Region make the band 5 mm taller or shorter, from 40 mm as it opens, between 5 and 200 mm. The other steps show the same band, and Implant planning saves its height with the plan.

With By Points, click the curve's points starting from either end of the jaw. The panoramic always starts at the curve's end towards the patient's right. In the cross-section, B marks the cheek or lip side and L the tongue or palate side, whichever way you drew the curve.

Confirm the cheek side

Implant planning needs to know which side of the curve is the cheek's. It knows for a curve from Automatic CPR Localization. For a curve you draw with By Points from nothing, it asks you:

  1. On CPR Settings, look at the axial view. Short marks stand all along the curve, on the side Implant planning suggests for the cheek, with a B at both ends and in the middle.
  2. The panel asks Is the cheek on the side marked B, all along the curve? Check every mark against the anatomy.
  3. Click Yes, or No, the other side. If only some marks are on the cheek's side, the curve turns back on itself: move or delete points first.

Until you answer:

  • The cross-section and the Implant Report show no B and L.
  • Pin Planning adds no pin, and the implant library adds no angled abutment. Both are placed towards the cheek, so a Warning asks you to confirm the side first. Implants, straight abutments, nerves and measurements work as usual.
  • A new implant copies the last one's choice with a straight abutment in place of an angled one. So do the implants Initialize Implants adds.
  • An abutment's rotation shows – and can't be changed, because its number is read from the cheek side. A message under Abutment says what to confirm. Use Prosthetic Axis still works.
  • A tooth set up alone in its jaw gets no crown. One landmark doesn't show which way the tooth faces, so Implant planning says so and places nothing. Confirm the side, or set the tooth up together with a neighbour.

The suggested side can be wrong, for example on a curve with a hook at its end. Always check the marks against the anatomy, all along the curve, before you answer.

Once the side is known, the marks stay beside the curve on CPR Settings, so you can always see what Implant planning takes for the cheek. If they are on the wrong side, click Wrong side? in the panel. This also corrects an automatic curve.

Your answer holds for the curve as it is. After you drag, add or delete a point, or tilt the curve's plane, Implant planning asks again: You changed the curve. Is the cheek still on the side marked B, all along it? Until you answer, the curve counts as not confirmed, and a Warning says The panoramic curve changed. Confirm the cheek side in CPR Settings. The same goes for an automatic curve and for one the AI drew, once you change it. Undo takes the change back, and your answer stands again. Reset, or deleting the curve down to one point, starts a new curve.

Draw a smooth line along the middle of the jaw, once from one end to the other. A sharp zig-zag reads as turning back. If the curve turns back on itself, Implant planning can't tell the cheek side along it. This happens when a point is clicked or dragged behind the one before it, when the curve loops, and when a whole arch is confirmed the wrong way round. Then:

  • The panel says This curve turns back on itself, so Implant planning can't tell the cheek side along it. Move or delete the extra points, or use Automatic.
  • The marks beside the curve go, and the curve counts as not confirmed: no B and L, no new pin, no new angled abutment.
  • Abutments already placed stay where they are.

Move or delete the extra points, then answer the question again, or click Undo. If you answered the question the wrong way round, click Wrong side?.

If two points end up on the same spot, the panel says This curve is too short to show the cheek side. Add a point further along the jaw. Implant planning doesn't save such a curve with the plan: after a reload, draw it again.

Nothing moves in the patient when you answer, click Wrong side?, reset the curve or draw it again: the crosshair, the cross-section and every abutment stay where they are. If the curve runs from the patient's left, the cross-section's tilt changes sign. An angled abutment's rotation is read along the curve, so its number can differ until the side is confirmed and after you redraw the curve, while the abutment stays put. One Undo takes the answer back.

A plan saved before Implant planning kept the cheek side opens exactly as it was saved, and a message asks you once to confirm the side on CPR Settings. This includes a plan whose curve the AI drew: the curve may have been redrawn by hand since, so check the marks and answer. When a plan or a version opens, the panoramic's offset and the cross-section's tilt start at 0.

The black around the band isn't part of the image. A click there places nothing and leaves the crosshair where it is. An implant, a nerve point or the crosshair dragged out of the band stops at its edge. You can still pan, zoom and open the view's menu there.

While you draw the curve with By Points, or edit a nerve, right-click a point to delete it: the point turns green and the menu offers Delete Point alone. A right click anywhere else opens the view's usual menu. After the delete no point is selected.

On Nerve Settings:

  • Click a nerve's card to edit it. Its Add Right Nerve or Add Left Nerve button stays lit while you do. Click Finish Drawing to stop editing.
  • Diameter goes from 0.1 to 10 mm in steps of 0.1. A typed value keeps one decimal: 2.46 becomes 2.4.
  • While you edit the left or right nerve, the panoramic shades the other half of the arch. It shades neither half until the curve's cheek side is confirmed.

Adjusting an implant

On the Implant Planning step, click an implant's tooth on the chart to select it. Then put the pointer over a view and use the keys:

  • ↑ or W and ↓ or S move the implant along its own axis. ← or A and → or D move it to the left and right of that view. Each press is one Precise movement step from Settings (0.25 mm).
  • + or Q turns it counter-clockwise about its platform, and − or E clockwise. Z turns it clockwise about its apex, and C counter-clockwise. Each press is one Precise Rotation step (0.20°).
  • Shift and Alt change nothing. Each press is one Undo step.
  • When a press starts or ends a collision, the Warning comes up straight away. Press Enter to close it and carry on: the keys still act in the same view while the pointer is over it. If you moved the pointer off that view while the Warning was up, put it back over a view first.

In the views:

  • Drag the round arrow beyond either end of the implant to turn it about the other end. One sits 5 mm beyond the apex, the other 5 mm beyond the sleeve's seat. When the view is zoomed out they stand further out, clear of the move handle, of every step button and of each other, so a press on one never lands on another control.
  • A round arrow that would fall outside the view, or in the black around the panoramic's band, stands at the nearest place you can press instead. A thin line joins it to its end of the implant. A step button that would fall there isn't shown.
  • An implant seen end-on has no round arrows: turning it about the line of sight wouldn't tilt it. Turn it in another view.
  • The pale outline round an implant is its security zone, as wide as Security Zone Size in Settings. Beyond the apex it ends in a point that far out. It stops at the platform. Implant collision shows as soon as two implants' outlines overlap as they are drawn, before the implants themselves touch.
  • A right click on an implant's or a pin's handle opens no menu. Right-click the image beside it for the view's menu.
  • After you turn a pin with one of its round arrows, the views are cut through the pin again, and the axial view tilts to lie along it. Moving a pin leaves the views where they are.

In the panel:

  • Under Abutment, the slider and its number turn an angled abutment about the implant, from −180° to 180°. At 0° it leans along the curve: towards the back of the mouth on an upper implant, and towards the front on a lower implant. At 90° it leans to the right in the cross-section, in both jaws: to B (cheek or lip) on the patient's left half of the curve, and to L (tongue or palate) on the right half. −90° is the other way, and 180° and −180° are the same lean.
  • A new angled abutment starts at 0°. An abutment from an older plan keeps the way it leans: one that leans to the cheek reads 90° on the patient's left half of the curve and −90° on the right half.
  • Use Prosthetic Axis is one switch for every implant. While it is on, the slider starts at 0° and turns the implant itself about its abutment's axis. The platform stays where it is and the abutment keeps its direction, while the apex swings round. Each change is one Undo step and can start or end a collision. Switch it off to turn the abutment again.
  • With Use Prosthetic Axis on, the slider is greyed for a locked implant, and for an implant with a straight abutment or none. The number goes back to 0° when anything else changes the implant or the panoramic curve: another abutment, a move, a new length, Undo or a new curve. The slider then turns from where the implant is.
  • Sleeve Distance / H(sl) moves the sleeve along the implant in steps of 0.5 mm, from 0 to 100 mm. While the sleeve is off its standard height, the chart says by how much under the collisions, for example Sleeve changed +0.5mm.
  • With Show all off, the library lists the implant maker's sleeves the implant fits through. When a maker makes one sleeve per implant diameter (Dentaurum's pOsition, one colour each), only the one made for the implant's diameter is listed.
  • Some implants are longer than their size's name, or wider at the top. Where the maker says so (IML's 6 mm Universe is 7 mm long, for example), the implant is drawn, checked for collisions and exported at the maker's real size: its platform stays where it is and its tip goes deeper. The size keeps the maker's name. The panel shows the real number beside it, for example 6mm (real 7mm), and the reports add real: 7 mm long. A plan holding such an implant opens only in an up-to-date Implant planning: an older one refuses it rather than read the name as the real size.
  • Pick size again shows on an implant planned in an older Implant planning (a tab left open, an older desktop app) whose size the maker makes bigger than planned, or which doesn't say which of two platforms it is. Guides, reports and exports wait until you pick its size again in the library.
  • Sleeve too narrow shows when the implant can't pass through its sleeve's hole (the generic sleeve's is 5.05 mm), counting a shoulder wider than the implant (Straumann's WN is 6.5 mm). Create Guide, Finalize, the Implant Report, the Drill Report and every export except Anatomy wait until you pick a sleeve the implant fits through. A pilot sleeve, which guides the drills only (Straumann's Ø2.2 and Ø2.8), doesn't count: the chart reads Pilot sleeve: implant placed by hand.
  • A sleeve from another maker than the implant's, picked with Show all, reads Sleeve changed on the chart at its standard height too.
  • A changed sleeve is drawn yellow in every view and in the panel, and the selected implant's number on the chart turns yellow. While the implant collides, the sleeve is red with it.
  • A tooth that has a wax-up crown and no implant is pale blue on the chart, whether the crowns are shown or hidden. Click it to add that tooth's implant, as on any other tooth.
  • Anatomy collision also shows when only the sleeve touches the Anatomy scan, a neighbouring tooth for example. Moving the sleeve clear ends it. A surface that only passes through the sleeve's hole, without reaching its wall, doesn't count.
  • Sleeve collision shows when the sleeve touches another implant's sleeve, or stands in an object that is not anatomy. See The Objects list for which objects count.
  • The padlock locks the implant. Its three pencils are greyed until you unlock it, and the keys and the turning handles leave it where it is.
  • The implant's eye hides its sleeve with it, and the sleeve's eye closes too.
  • Secondary Components is one switch for the panel and the implant library: turned on in one, it is on in the other. The Analog Extrusion row's eye is greyed: the analog shows in Analogs Model only.

Designing a guide and a model

Guide Design opens Select Design. Guide designs the surgical guide and Analogs Model the printable model.

Each needs a scan placed on the CBCT to design on, and nothing else. Both open with no implant planned: the cross beside Implant plan under each tells you so.

  • A guide made with no implant has no sleeve hole, and Create Guide says This guide holds no sleeve: no implant is planned in its jaw, and no pin with a sleeve. Plan the implants and click Finalize to make the guide again with their sleeves.

  • A model made with no implant in its jaw is a plain model with no analog hole. Create Model then shows no Analog Tolerance, and Finalize Model no Analog Holes. Plan the implants and build the model again to get their holes.

  • Sleeve Tolerance (on Guide Generation) and Analog Tolerance (on Create Model) are added to the hole's diameter. At 0.12 mm, a 6.30 mm sleeve gets a 6.42 mm hole and a 4.10 mm analog a 4.22 mm hole: a gap of 0.06 mm all round.

  • A guide or model finalized before that keeps its wider holes. Its panel and the export dialog then say This guide was finalized with an earlier tolerance rule (or This model), with how much wider the holes are. Click Finalize again to apply the tolerance as shown.

  • Add Sleeves Support Top Protection (on Guide Generation) is off when the page opens. Switched on, the guide gets a ring 1 mm wide standing 0.5 mm above each sleeve's top, just outside its hole. Leave it off if your drill handle or stop is wider than the sleeve, as it could rest on the ring.

  • Finalize Model starts with Analog Holes. Bottom Extrusion is the diameter of a hole from each analog's platform down through the base, for pushing the analog out. Top Extrusion is the diameter of an opening from the platform out through the gum. Each takes 0.1 to 10 mm in steps of 0.1, and they start at 2.2 mm and 6.2 mm. The gold and blue cylinders in the view show both sizes as you change them.

  • Click Apply to cut both holes at every analog. The model is built again, which takes a few seconds. While it builds, and while the holes are applied, the two boxes are greyed. Applied, they show the sizes that were cut. Click Clear to take the holes back, then change the sizes and click Apply again. Apply and Clear are one Undo step each.

  • Apply refuses a Bottom Extrusion as wide as an analog, because the analog would have no floor to sit on. A Warning names the tooth and nothing changes. Choose a smaller size. Any narrower size is yours to choose, however thin the ledge it leaves.

  • Apply also refuses a hole too narrow for the model to carry. The Warning gives the smallest diameter this model takes, usually 0.4 mm.

  • Until you click Apply, the model has each analog's own hole and no hole through the base. Untick a tooth's rows in the module's Objects list to hide the cylinders and see the cut.

  • Export All holds a Top Extrusion and a Bottom Extrusion file for each analog of a model finalized with holes, each long enough to pass right through the model. A model finalized before Analog Holes existed keeps its fixed hole through the base until you finalize it again.

  • If Implant planning says that how a guide or model was finalized can't be read by this version, click Finalize again. Until then it isn't exported.

  • The object list on Undercut Generation and on Edit Model offers every object placed on the CBCT: the Anatomy first, the segmentations last. Implant planning never starts a design on a segmentation by itself, so pick one from the list if you want it.

  • In the guide module's Objects list, an implant's first row gives its size, for example 24 Implant: ⌀4.1 x 10.

  • Under Offset By Brush on Undercut Generation, From View paints only the surface turned towards you. The far side of the model stays unpainted, as with the same switch under Edit.

  • In Text Options, with Along Curve off, one click on the guide or the model places the text there, and Generate Text is greyed. With Along Curve on, click the points of the curve, then click Generate Text.

  • Pin Sleeve Support starts at the widest pin sleeve in the plan: with a 3.5 mm pin sleeve it goes from 3.5 to 20 mm. With no pin it starts at 0.

  • Implant Sleeve Support starts at 7 mm. While the guide's jaw has no implant it starts at 0.

  • Sleeve Index is listed under Advanced Options only when the plan has a sleeve for the guide to hold: an implant in the guide's jaw, or a pin with a sleeve.

  • Delete Guide also removes the guide's texts and its Sleeve Index. Undo brings them back.

  • When Implant planning asks whether to edit the guide or model that already exists, Yes has the focus: press Enter to open it.

  • A value typed with more decimals than its box shows loses the extra ones: 0.555 becomes 0.55.

Placing wax-up crowns

On Teeth Setup, the wax-up wizard's Teeth Landmark page shows the next tooth's number by the pointer while it is over the model. Off the model, the number stays where the pointer left it.

The Teeth Placement page moves the crowns. Open Manual Mode:

  • With Select Individual, drag a crown to move it. In Rotate, a drag of 100 px is a quarter turn. Vertical turns the crown only about the screen's vertical axis, as you drag left or right. Horizontal turns it only about the horizontal axis, as you drag up or down.
  • In Scale, drag away from the middle of the crown to enlarge it and towards the middle to make it smaller. The crown follows from the first pixel, also when the drag starts on its middle. One drag makes a crown at most four times and at least a quarter of its size: drag again to go further. Hold Shift and drag to scale a crown whatever Placement Mode is set.
  • With Manual Selection, click a crown to select it. It stays white and the other crowns turn lavender. Drag the selected crown to move it. A drag that starts on another crown only selects that crown.
  • Hold Alt and click to add a crown to the selection or take it out. With two or more crowns selected, the widget appears by itself and moves them together.
  • With Re-Orientate Widget on, an arrow moves the widget itself and leaves the crowns where they are. Undo doesn't take that move back.
  • With a switch under Collision Options on, a crown you drag into its neighbour stops where the two touch. The neighbour doesn't move.
  • While Adapt Crown (Antagonist Required) is on and the wax-up has a scan of the opposing jaw, the Collision Options and Activate Widget are greyed. Switch it off to use them.

In Chain Mode, click a crown to put the widget on it:

  • Move and Rotate act on that crown and on its neighbours within Reach. Drag one of the four small olive balls outside the Reach ball to change Reach. The slider follows. This takes no Undo step.
  • Re-Orientate Widget shows under Move only.
  • Bend greys the crown you clicked and the crowns behind it on the same side. That part bends.
  • With Mirroring on, a Move also moves the matching teeth on the other side, mirrored. The mirror tooth's neighbours follow it as the dragged tooth's do.

In Anatomical Mode, each crown has a ball beside it. A red ball holds its tooth in place and a green one lets it move. As the mode opens, the two end crowns of a row are red and the crowns between them green.

  • Drag a crown to move it together with every green tooth. The crowns are resized so that the row stays closed.
  • Hold Shift and click a ball to turn it red or green.
  • Hold Ctrl and drag a crown to move every tooth together, without resizing.

The 3D toolbar's Show Mandibular Teeth Only, Show Maxillary Teeth Only, Show All Teeth and Hide All Teeth show and hide the crowns. Each press is one Undo step. The Objects panel lists the crowns from the patient's left to the patient's right.

On Set Teeth Markers, click a tooth on the map, then click in the 3D view to put its marker there. You can also drag the marker's dot.

The Implant Report

Implant Report under Reports / Export opens Implant Report Settings before it makes the PDF.

  • Font color: colours the page titles, the section headings, the labels, a table's heading row, the notes at the foot of each page and the page number. The values beside the labels, the patient and project at the top right and the captions under the pictures stay black.
  • 3D template: changes the report's 3D pictures only.
  • Your logo prints at the bottom left of every page, 160 pt wide (about 56 mm) in its own shape. A logo less than four times as wide as it is tall prints 40 pt tall instead, so it is narrower.
  • The logo you pick with Change Logo Image is kept in this browser for every case. Making a report never changes it. It changes only when you pick another image and click OK.

The Objects list

The Objects panel on the 3D view lists the case's objects, segmentations, implants, nerves and pins. Tick a row to show it and untick it to hide it.

  • An implant's row shows the implant's colour. It turns the collision colour (red, unless you changed it in Settings) while the implant collides with a nerve, another implant, a pin or the Anatomy. Against the Anatomy, the implant's sleeve counts too.
  • Which line the Warning gives for an object depends on the object's type. The Anatomy and an Antagonist give Anatomy Collision, whether the implant or its sleeve reaches them. A Waxup-Prosthesis the implant itself enters gives Anatomy Collision too.
  • A sleeve that stands in an object of any other type gives Sleeve Collision: a prosthesis scan, an imported guide, a bone graft, a marker scan, a bar, an object typed Other. A hidden object counts. An object not yet placed on the CBCT doesn't, and neither do the Segmentations, unless you gave one the type Anatomy or Waxup-Prosthesis yourself.
  • One object can give both lines: a prosthesis that the implant enters and its sleeve stands in is listed with Anatomy Collision and Sleeve Collision.
  • A guide or model you designed in Implant planning is never counted against the sleeves it was made for. If you move an implant afterwards, finalize the guide again: the export tells you when a guide no longer fits the plan.
  • Change Object Type in an object's menu runs the check at once.
  • A Warning names the colliding implants when the case opens and when a collision starts. Click OK or press Enter to close it. Esc doesn't.
  • The collisions are checked again when you let go of an object you moved with its Move handle in the 3D view, and when you click OK in Settings. The Warning comes up if the list changed.
  • An implant nearer to a nerve canal than Minimum Distance From Nerve in Settings is listed with that nerve's Collision Zone. The distance is the bone left between the implant's surface and the canal's wall: at 2.00 mm, an implant with 1.75 mm left below its apex is listed, and one with more than 2 mm left is clear. With Nerve warning off, only an implant that reaches the canal itself is listed.
  • Implants is listed once the plan has an implant.
  • Pins is listed once the plan has a pin. Click a pin's name to select it. Its menu has Hide Pin, Delete Pin, Lock Pin, Lock/Unlock All, Edit Notes and Transparency (Opaque, 20%, 50% or 80%). Notes and transparency are saved with the plan.
  • Lock/Unlock All, in an implant's menu or a pin's, locks every implant and every pin together. When all of them are locked, it unlocks them all.
  • Show/Hide Implants on the 3D toolbar hides the pins with the implants, in the 3D view and in the 2D views. While they are hidden, the keys don't move the selected implant or pin. Sleeves and abutments follow their own buttons, Show/Hide Sleeves and Show/Hide Abutments, in every view.
  • A pin collides with an implant it passes through and with the Anatomy scan. Its marker on Pin Planning turns red, and the Warning lists the pin with Anatomy Collision.
  • Under Segmentations, the teeth come first, then the jaws.
  • Duplicate Object in an object's menu adds a copy in the same place, shown or hidden as the object is. The copy keeps the object's name, as type Other (Anatomy (Other), Upper (Other)). A second copy takes _1 after the name, the next _2. The copy of an object with no type, such as a guide's text, takes its name with _copy after it, and so does each further copy: use Rename Object to tell them apart.
  • In the 3D view, a right click on an object opens its menu. A right drag opens no menu, wherever you let go.
  • Change Color on a scan that has colours of its own (a texture, or a colour for every point) changes its swatch in the list and its outline in the 2D views. In the 3D view and on its card the scan keeps its own colours.
  • With Show/Hide DICOM off, changing step or clicking Reset fits the 3D view to the objects that are showing, not to the whole CBCT.
  • Capture Screenshot on a view saves that view's picture to your computer and says Screenshot saved, as Screenshot beside Layout does. Both pictures show the side letters of the 2D views.

Trimming and sculpting the CBCT

On VOI Settings:

  • Turn Trimming on to show the trim box. A handle is blue while the pointer is on it; drag it to move that side of the box. On the 3D view, holding Ctrl makes no difference, and with Alt or Shift held the handle doesn't move.
  • Permanently Trim asks first, then cuts the CBCT down to the box for good.
  • Start Sculpting turns Trimming off and lets you draw, on the 3D view, what to remove. Click Start Sculpting again, or Cancel, to leave without removing anything.
  • Click to add points, or hold the button and draw a loop. You can draw several loops before you click Sculpt. Every loop is tinted magenta, and the tint shows exactly what Sculpt removes, through the whole depth: all of every loop, and nothing between two loops. Where two loops overlap, the overlap is removed too.
  • A right click takes the last point back.
  • Invert tints, and removes, everything outside the loops instead.

On 3D Settings, Save Template with a template selected adds a copy named after it (Default (copy)) and leaves the template selected. Saving the same template again adds Default (copy) (copy). Picking a template under Templates also sets the shading back to Bright.

In the implant library, Layout opens Change layout. A click on a layout applies it at once, behind the dialog. Cancel puts back the layout you had.

In a 2D view, a right drag that starts on a handle (an edge of the trim box, an implant's move disc) doesn't zoom. It opens the view's menu where you let go.

Objects on Data Import

On Data Import, each object has a card under 3D Objects.

  • A card shows the object's whole name, on as many lines as it needs.
  • In Matching: STL on DICOM, By Points pairs the markers by the order you place them. The first six pairs have their own colours and further markers are grey-white. Diameter keeps one decimal of a typed value: 4.56 becomes 4.5.
  • In Matching: STL on STL, By Points numbers the points on each object. A number has the same colour on both objects, so you can see which points pair up.
  • Each point stands in a see-through sphere as wide as Matching Diameter: the surface inside it is what the fit matches on. Matching Diameter is set in whole millimetres.
  • Fit with more points on one object than on the other shows a Warning: The number of points is inconsistent. The minimum of the two will be used. Click OK to fit on the pairs alone. The points without a partner are left out.
  • Click By Points again to switch it off: every point is cleared. Accepting a fit with OK in Registration Error clears them too.
  • Each point you place is one Undo step. Undo takes back the last point alone, on whichever object it stands, and Redo puts it back. By Points stays on.
  • With By Brush, Clear Left Area, Clear Right Area and Clear All Areas are greyed until there is something painted to clear. Fit needs an area on both objects.
  • Boolean Operations opens on the Anatomy and on the object that follows it in the lists, whichever card is selected. Pick another object from either list.
  • A result of Merge to..., Subtract from... or Intersect with... takes the type and colour of object B. With a surgical guide as B it is listed as Boolean 1 (Surgical Guide) and has the guide's colour. A result of Remove intersections with... or Cut with surface... is what is left of object A, so it takes A's type and colour. A result never takes the type Anatomy, because a case has one Anatomy.
  • Subtract from... takes object A out of object B. Cut with surface... keeps the part of object A that lies behind B's surface: inside B when B is a closed object. When nothing of A lies there, a message says Boolean Operations failed: Nothing is left: the objects don't overlap that way. and no object is added.
  • With Copy the result as a new Object off, the result takes the place of the object it is made of: object B for Merge to..., Subtract from... and Intersect with..., object A for the other two. The other object is left as it was.
  • Edit opens any object, also one left at the type Face Scan. Only a face scan that came with its picture is refused, with Face scan editing is not supported.
  • Under Edit, Boundary Straightening opens with one open edge picked, shown green: the edge of the largest opening. Click another edge to add it, or use Select All.
  • In the Freeform Tools, Add, Remove and Scrape open at a Tool size of 3.0 mm and a Tool strength of 20, Smooth and Fill at 2.0 mm and 10. Each tool keeps the values you give it until you leave STL Edit.
  • Under Edit, Remove Isolated Components opens with Size Ratio at 0 % and nothing highlighted. Raise it to highlight the small pieces, then click Remove.
  • Split Isolated Components adds each separate piece as a new object, named after the object with - Split and a number from 0. The object you are editing stays whole.
  • Merge Isolated Components lists the case's objects. Tick two or more and click OK. They become one new object, named after the object you are editing with - Merged. The objects you ticked stay as they are.
  • A tool's section closes when its button has done its work: Offset, Apply under Mirror, and Cut under Area, Brush and Lasso. Click the tool again to carry on.
  • With Lasso, start the loop on the object. A drag that starts beside the object turns the view.
  • A cut with Save Cut Part on adds the cut part as a new object, named after the object with - Cut.
  • Offset with Save As Separate Parts on leaves the object as it was and adds two new objects named after it: - Offset, the painted part moved, and - Cut, the object without that part.
  • Tool Size under Cut By, Brush moves in steps of 0.5 mm.
  • Under Mirror, drag the dot at the centre of the ring to move the mirror plane, and drag the ring to turn it. Apply mirrors the object about the plane where it stands.
  • In the 2D views, a scan's outline has the colour you gave the scan, or the colour Settings gives its type. This holds even when the 3D view shows the scan in its file's own colours.
  • After a fit in Matching, STL on STL, the Registration Error colour bar is marked at every fifth of its scale: 0.00 to 1.00 mm in steps of 0.20 as it opens.

AI segmentation

Implant planning's AI segmentation finds the jaws, the teeth and the nerve canals on the CBCT. It runs in Smileline's cloud or on your computer's own graphics card (see Where the AI runs). When it runs on your computer, your scans never leave your computer.

It runs as each CBCT opens, behind the case, so you can plan while it works: on your computer, about a minute for a small scan, a few minutes for a 15 cm field. Automatic Segmentation on Data Import and Automatic Nerve Detection on Nerve Settings then use its result. After you change the CBCT under VOI Settings, it runs again when one of them needs it.

When you open a CBCT for the first time, Implant planning finds its arch from the grey levels at once. Once the AI has run, the AI's arch curve takes its place, unless you changed the jaw or the curve meanwhile, and Implant planning finds the nerve canals once any tool you started meanwhile has finished. While STL Edit, Boolean Operations or a wizard with its own Undo is open, both wait for it to close. Undo takes each back on its own. A case you open again keeps its saved curve and canals.

  • The first time the AI runs on your computer, Implant planning asks Download the AI model? Click Download to download it once (62 MB). Implant planning keeps it on your computer and doesn't ask again. If your browser can't keep it (a private window, say, or a full disk), Implant planning asks again the next time.
  • Not now leaves the AI out, and the tools work without it. Implant planning doesn't ask again in that browser tab, even after you reload it. To download the model later, open Implant planning in a new tab.
  • While the model downloads and the AI works, a bar at the bottom of the window shows how far it has got. Cancel stops it, and a tool waiting on it stops too.
  • On a computer whose graphics card can't run it, the AI can still run in the cloud. When it would run on your computer, Implant planning says AI segmentation needs a newer graphics card. once in that browser tab, and the tools work without the AI, as before.
  • If you move, edit, show, hide or delete one of the segmentation objects while the AI works, or have STL Edit or Boolean Operations open, Automatic Segmentation keeps your objects as they are, adds none, and asks you to run it again.

Where the AI runs

The AI runs in Smileline's cloud or on your own computer. Either way, its result is a starting point that you check and correct.

  • In the cloud, the AI is usually done in under a minute, where your computer takes a few. Where the cloud is available for your practice, Implant planning asks Run AI segmentation in Smileline's cloud? before it sends a scan, once in each browser tab. Click Use the cloud to send the scan, or On this computer to keep it on your computer and run the AI there.
  • The first scan in a while takes longer. The cloud AI isn't kept running while nobody uses it, so it may have to start first. Implant planning shows Starting the cloud AI… meanwhile: usually a moment, up to a few minutes the first time in a while. It sends nothing of the scan until the cloud AI is ready.
  • What is sent is the scan's images, with their size and position, and a pass that lasts three minutes and is good for that one scan. The patient's name, date of birth and other details are not sent, and nor is your name or your practice's. The images are still the patient's health data.
  • Who processes it is Modal, a company in the United States that Smileline uses as a processor for this step. Modal keeps a copy of the scan and of its answer for up to 7 days, encrypted, in the United States, and then deletes them. Modal is on the list of sub-processors in Smileline's Data Processing Agreement.
  • Smileline records that it let a scan of this patient go to the cloud: for which patient, by whom and when, like any other read of the patient's record. It records this just before the scan goes, after you clicked Use the cloud and the cloud AI has started. The record says the scan was allowed to go, not that it arrived. Nothing is recorded when you choose On this computer, or when the cloud AI doesn't start.
  • The answer is kept with the plan on the patient's record, like the other files Implant planning makes, and doesn't show on Files. Implant planning saves it there as soon as it has it. When you open the case again, Implant planning reads it from there and sends nothing.
  • When the cloud can't be reached, Implant planning says so and runs the AI on your computer instead. Where your practice's account has no cloud AI, it doesn't ask and runs the AI on your computer. A scan stored at an angle to the patient's own axes, or with a different spacing in one direction, always runs on your computer.

In the cloud, the AI uses DentalSegmentator with TAPSeg (Zhang et al., Apache-2.0), which tells the teeth apart.

While the AI runs in the cloud

  • Implant planning asks Run AI segmentation in Smileline's cloud? only where it can use the cloud. Where the cloud isn't set up for your practice, it doesn't ask and says nothing: the AI runs on your computer.
  • If your role can't add to the patient's files, Implant planning doesn't offer the cloud either, because its answer couldn't be kept with the patient's files: the AI runs on your computer. An answer already kept with the case is still used.
  • Your answer to Run AI segmentation in Smileline's cloud? holds for that browser tab, even after you reload it. To choose again, open Implant planning in a new tab.
  • The bar at the bottom of the window shows Preparing the scan for the cloud… while your computer gets the scan ready, then Starting the cloud AI… until the cloud AI is ready (see Where the AI runs), then Sending the scan to the cloud… with how much has gone, then AI segmentation in the cloud… while the AI works. Once the answer is in, a line in the same place shows Keeping the cloud AI's answer… while Implant planning saves it to the patient's record.
  • Cancel stops it, and a tool waiting on it stops too. Once a scan has started on its way, it isn't sent a second time: if the AI is then needed again for the same scan, it runs on your computer. Before that, nothing was sent, and the next tool that needs the AI tries the cloud again. If Implant planning had already checked the cloud's answer against the scan when you clicked Cancel, it keeps the answer all the same, and uses it the next time the AI is needed for that scan.
  • Cancel while the bar shows Starting the cloud AI… stops the waiting only: Implant planning goes on with the AI on your computer and shows no message. Nothing of the scan was sent, and the cloud is tried again as below.
  • If the cloud AI hasn't started within five minutes, Implant planning says The cloud AI didn't start in time. Try again in a few minutes, or run the AI on this computer. and goes on with the AI on your computer. Nothing of the scan was sent. To try the cloud again, open the case again a few minutes later; if the AI didn't run on your computer either, running Automatic Segmentation or Automatic Nerve Detection again tries it too.
  • If your computer can't get the scan ready to send, usually because it is short of memory or disk space, Implant planning says Implant planning couldn't prepare the scan on this computer for the cloud AI. Free some disk space or memory and try again, or run the AI on this computer. and goes on with the AI on your computer. Nothing was sent, and the cloud is tried again as above.
  • If the cloud can't be reached, hasn't taken the scan within a minute and a half, or hasn't answered within two and a half minutes of starting to send it, Implant planning says Cloud AI segmentation isn't available right now. and runs the AI on your computer, as above.
  • If the cloud's answer is damaged, cut short or not the answer to the scan you sent, Implant planning says Cloud AI segmentation gave an answer Implant planning couldn't read., keeps nothing of it, and runs the AI on your computer.
  • As soon as Implant planning has the cloud's answer, the tool waiting on the AI goes on, and Implant planning saves the answer to the patient's record with the plan, without waiting for the next save. You can keep working meanwhile: the line Keeping the cloud AI's answer… stays until Smileline has it. Until then, Implant planning asks before you leave the tab: if you leave anyway, the answer is lost, and the scan is sent again the next time.
  • Exit, or opening another CBCT, doesn't stop that save: the answer goes to the plan of the case it belongs to, never to the one you have open. Where Implant planning can't save that plan from there (the case has no plan yet, or its files were let go when the other CBCT opened), the answer waits in the tab and is saved once you open that case again in it. Implant planning still asks before you leave the tab until then.
  • If Smileline can't be reached while the answer's file or the plan is saved, the line shows Couldn't keep the cloud AI's answer yet. Trying again… and Implant planning keeps trying by itself.
  • If the answer can't be saved yet, because Smileline refused its file or the plan changed somewhere else, Implant planning says Implant planning couldn't keep the cloud AI's answer on the patient's record yet. Keep this tab open until the plan is saved. The tools use the AI's result meanwhile. The line under the top bar says what to do (see Files the plan uses and When the plan changed somewhere else). Once the plan is saved, the answer is kept with it.
  • When you open the case again, the bar shows AI segmentation: opening the saved result… while Implant planning checks the kept answer against the scan, then uses it: it doesn't ask, and sends nothing. After you change the CBCT under VOI Settings, the kept answer no longer fits the scan, so the AI runs again.
  • If the kept answer can't be read when you open the case again, or its file is no longer on the patient's record, Implant planning says Cloud AI segmentation gave an answer Implant planning couldn't read. and runs the AI on your computer. It doesn't send that scan to the cloud again, however often you open the case.
  • Changing the CBCT under VOI Settings doesn't lose a kept answer: the plan keeps it, and if the scan goes back to how it was (after Undo of a sculpt, say), Implant planning uses it again and sends nothing.
  • The plan is saved only once the cloud's answer is on the patient's record, as for any file the plan uses (see Files the plan uses).
  • If Smileline no longer lets you see the patient, nothing is sent and the AI doesn't run on your computer either: Implant planning checks your access, as under Signing out closes the case.

The cloud numbers the teeth, and says for each jaw how sure it is. What Automatic Segmentation then names each tooth tells you which of three cases it is:

  • Sure of the jaw's numbers: its teeth are named plainly, Tooth 36.
  • Unsure of the jaw's numbers: Implant planning says AI segmentation: check the tooth numbers in the lower jaw. (or the upper jaw, or both), and names each tooth of that jaw Tooth 36 (check number), in the Objects list and in the files you export.
  • The jaw wasn't numbered: Implant planning numbers its teeth itself, by their place along the arch, says the same message, and names them (check number) too.

Check each such tooth against the scan. Then use Rename Object to give it its name: the name you type replaces (check number). The other jaw's teeth, and teeth the AI found on your computer, are named plainly.

Canals the AI finds

  • Each canal the AI finds shows AI, unconfirmed on its card under Nerve Settings. Where the AI found no canal and drew the line straight across, that stretch is dashed in the 2D views and see-through in 3D.
  • Click the card to check the canal in the views, then click Confirm. The card then shows AI, confirmed.
  • When the AI finds one canal only and can't tell its side, Implant planning shows the canal in the views, moves them to it, and asks Which side is this canal?: click Right or Left. If that side already has a canal, the new one isn't added.
  • Moving, adding or deleting a canal's point takes its confirmation away, and its dashes too: check the canal again and click Confirm.
  • The Implant Report under Reports / Export lists each canal the AI found as AI, unconfirmed or AI, confirmed, with the AI model it came from, and dashes their drawn-across stretches in its pictures.

AI segmentation uses DentalSegmentator (Dot et al., CC BY 4.0, Zenodo 10829675), converted to ONNX by Smileline.

Signing out closes the case

Whenever you come back to its tab, Implant planning checks your sign-in and reads the patient's documents again, which is recorded like any other read of them. Implant planning closes the patient's case and clears everything it held of the patient if any of these happened:

  • you signed out of Smileline or switched practice or account;
  • you can no longer see the patient's documents;
  • the patient's record was erased or restricted.

It then asks you to sign in again. What was saved to the patient's record stays there; changes not saved yet (the top bar doesn't say Saved) are lost, so wait for Saved before you sign out or switch practice.

Saving your work

Implant planning saves the plan to the patient's record as you work, a moment after each change. The top bar shows Saving… while a change is on its way and Saved with the time once Smileline has it. When you open the same CBCT from the patient's record again, on this computer or another, the plan opens as it was saved, at the resolution it was read at. Within the same tab, Exit takes you back to the patient's files.

Implant planning asks before you leave the tab only while something isn't saved yet.

Versions

Click Versions in the top bar to keep the plan as it is now under a name (Save version), and to open or delete the versions kept. Save As saves a version too. If a version already has that name, Implant planning asks Project already exists. Do you want to replace it?: Yes replaces it, and No takes you back to the name. Versions are kept on the patient's record with the plan. Once the version is kept, Save Project reads Project saved and says where it is. It stays open until you click Close. Save As writes no file: for one, click Versions, then Export the plan as a file. While a wizard is open, Save As answers Please exit the current wizard before saving. Start a new plan starts again with nothing planned: no implants, pins, nerves, measurements, wax-ups or designs. Implant planning finds the arch and matches the scans again; segmentations and a finalized guide or model stay where they are. Implant planning also keeps a version by itself:

  • before it opens another version (Before opening and the version's name), and before Start a new plan;
  • when you settle a clash with another tab (below);
  • when the saved plan can't be read whole by this version of Implant planning, or uses files Smileline no longer has. The case then opens without what's missing, and says so.

Opening a version downloads every file it uses first. If a file doesn't download, Implant planning offers Retry or Cancel: it never opens a version without a file that didn't download, and Cancel leaves the plan you have open as it is. A version that uses a file Smileline no longer has asks first, naming it: Open without them, or Cancel. A plan file dropped with its files (below) asks the same when the zip lacks one.

When the plan changed somewhere else

If someone saved the same plan in another tab or on another computer since you opened it, Implant planning stops saving and shows who saved it and when:

  • Keep mine keeps their plan as a version, then saves yours over it.
  • Reload theirs keeps your plan as a version, then opens theirs in its place. Undo goes back to yours.

Changes you make before you choose aren't lost: Keep mine saves them, and Reload theirs keeps them in the version of yours.

Files the plan uses

The plan saves only once every file it uses is kept with the case and on the patient's record. While one is still on its way, a line under the top bar says so. If Smileline can't be reached while one is added, Implant planning says so and tries again by itself (Retry now tries at once). If one can't be added for another reason, Implant planning says why and offers Retry; until then the plan isn't saved. A file Smileline kept instead of filing it waits under the unfinished uploads on the patient's Files tab, and Retry asks Smileline to file it again. If the plan names a file the case doesn't keep (an object whose file never came), Implant planning names it and saves nothing until it is kept: delete that object or import its file again.

When Implant planning can't save

  • Your role can't add to the patient's files: you can open the case and plan, but nothing is saved to the record. The top bar shows Not saved: view only.
  • The practice has no site to file the patient's files at: the same, until a site is added.
  • The plan is too large for the record (more than about 4 MB of plan data): the latest changes aren't saved, and Implant planning says so.

In each case, keep the plan with Plan file (or Versions) › Download plan with its files, before you close the tab. It downloads a zip with the plan and every file it uses. To open it again, open the same CBCT, then drop the zip on the Implant planning window. Export the plan as a file and Import a plan file still save and open the plan alone.

Files Implant planning adds to the patient's record

  • Files you import from your computer (Data Import, Upload File in Teeth Setup, or a file dropped on the window) are added to the patient's Files tab as 3D scans the moment they join the case. A file dropped on the window goes as soon as you drop it, so one Implant planning then can't read is on Files all the same.
  • Reports and exports you make under Reports / Export are added to Files too, as documents.
  • Files Implant planning makes for the plan (an edited object, a boolean's or a segmentation's result, a sculpted crown, the guide's block-out) are kept with the plan on the record, but don't show on Files. Only those the plan still uses are kept: one you undid or deleted isn't.

A file already on the patient's record is never added twice. Opened from the record, Implant planning doesn't open a CBCT dropped on its window: add the CBCT to the patient's Files tab, then open Implant planning from there.

Templates you save under 3D Settings last only as long as the tab: their pictures show the patient's scan, so Implant planning doesn't keep them.

Implant planning on your computer

Implant planning is also a free app for Mac and Windows, named SmileGuide. It works offline, AI included, and signed in to Smileline it opens your patients and saves their plans to their records, as in the browser.

Download it from smileline.io/download: Mac or Windows.

On a Mac, open SmileGuide.dmg and drag SmileGuide to Applications. On Windows, open SmileGuide-setup.exe and follow the installer.

Open SmileGuide.

Without signing in

The app opens a CBCT and scans from your computer: drop them on the window, or click Open folder or Open files. Your cases and their plans stay on this computer, under Recent cases, and no internet connection is needed.

The AI comes with the app, so it runs on your computer straight away: Implant planning doesn't ask to download it.

Your patients

On the app's start screen, click Your patients. Your browser opens Smileline's sign-in page: sign in as you usually do, Google included.

The browser hands you back to the app. If it asks to open SmileGuide, allow it; Open Implant planning on the page does the same.

The app lists your practice's patients. Search by name, date of birth or phone, and click a patient to open their CBCT and scans, as from their record's Files tab. The plan saves to their record as you work.

If the app says Sign-in didn't finish., click Try again to sign in again in your browser. Signed in, the app needs an internet connection.

  • Your patients at the top of a patient goes back to the list.
  • This computer's files goes back to the cases on your computer.
  • Sign out signs you out of Smileline in the app. Your patients then asks you to sign in again.
  • The app asks before it closes or leaves a case while something isn't saved yet: Your plan isn't saved yet. Leave anyway?

Updates

The app downloads its updates in the background and installs them when you quit it, so an update never interrupts a plan.

The AI model in the app is DentalSegmentator (Dot et al., CC BY 4.0).